A-100N FLEXFLO Peristaltic Pump

More Views

A-100N FLEXFLO Peristaltic Pump
$0.00

Availability: Out of stock

Patented TFD (Tube Failure Detection) system protects against chemical spills from a worn out tube and activates an alarm output relay

Self-Priming against maximum line pressure

Cannot Vapor Lock or Lose Prime

Four pump tube material options: Norprene®, Norprene® Chemical, Tygothane®, and FKM


Description

Details

Features:

- Peristaltic pump design does not have valves that can clog requiring maintenance.
- Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or lose prime.
- Outputs to 5.17 GPH (19.56 LPH).
- Output pressures to 100 PSI (6.9 bar).
- Output volume is not effected by changes in back pressure.
- Patented pump tube design installs easily and stays centered on the rollers without manual adjustment.
- Two pump tubes supplied with each pump. No extra tubing required.
- Accepts 4-20mA, 0-10Vdc, and Pulse inputs for manual or external speed control.
- Operator friendly digital touch pad.
- Easy to read LCD display
- Service and Alarm indicator icons.
- Display motor speed or input signal values.
- Prime mode for easy priming without changing programming.
- Built-in Tube Failure Detection system (TFD). Senses chemical in the pump head, shuts off the pump and activates a 1 amp alarm relay (dry contact closure).
- Compatible with Blue-White’s output flow verification sensor system.
- Durable housing of chemical resistant Valox (PBT) thermoplastic
Mechanical
Specifications:

Max. working pressure: ........100 psig (6.9 bar)
Max. fluid temperature: ........130 F (54 C)
Max. ambient temperature: ..14 to 110 F/ -10 to 43 C
Output adjustment range: ....5-100% in 1% increments (20:1 turndown)
Duty cycle: .............................Continuous
Maximum viscosity: ..............5,000 Centipoise
Maximum suction lift: ...........30 ft. Water 0 psig
Maximum Solids: ..................50% by volume
Enclosure: .............................NEMA 3R, (IP23)
Voltage (amp draw): ..............115VAC/60Hz, 1ph (.350 amp max)
230VAC/60Hz, 1ph (.173 amp max)
220VAC/50Hz, 1ph (.175 amp max)
240VAC/50Hz, 1ph (.193 amp max)
Power Cord Plug Type: .........115V60Hz = NEMA 5/15 (USA)
230V60Hz = NEMA 6/15 (USA)
Additional Info
A-100NV (digital display control)

- Manual or Automatic control
- Accepts 4-20mA, 0-10VDC, and pulse input signals
- 1 amp alarm output relay
- Digital touch-pad with LCD display
- Easy-to-read Service and Alarm indicator icons on LCD display
- Flow Verification Sensor (FVS) compatible.

A-100NF (dial knob control)

- Manual output control
- Easy Dial knob style – output percentage speed adjustment
- Nothing to program
- 5 – 100% output adjustment
- On-Off power switch